Is there a work around to this problem or should I consider it lost? To allocate in batch the coding should be: // SPACE=(CYL,(xx,yy,dd)) where xx is primary allocation, yy is secondary allocation, and dd is the number of directory blocks. blocks and Used dir. I typically allocation with 0 Blksize and let SDB (System Determined Blocksize) handle what it should be. news

The first volume introduces zPDT and provides reference material for zPDT commands and device managers. IBM manual has various explanation for BLDL or I/O processing error, but for the above I am unable to pin-point the exact cause. The correct coding for SYSUT2 is //SYSUT2 DD DISP=SHR,DSN=mypds(member) Second, the blksize is not optimal. A PDSE does not follow the same process so there is not really a comparison. have a peek at this web-site

I recovered the PDS from a DFHSM backup but when I try to browse any members I still get the I/O error. When opening for input, the priority order is reversed (DASD, JCL, program). MVSFORUMS.comA Community of and for MVS Professionals FAQ Search Quick Manuals Register Profile Log in to check your private messages Log in BLDL ERROR MVSFORUMS.com Forum Index -> We assume that the reader is familiar with general concepts and terminology of System z hardware and software elements, and with basic PC Linux characteristics.This book provides the primary documentation for

For some reason the storage group is NOT backed up so I cannot restore it from an old backup. If the incorrect output DCB was specified in a program, it needs to be fixed there: this program should then be rerun to open the PDS with its correct attributes; then zPDT is a PC Linux application. If there were members and now it shows 0 Dir Blocks, then someone used an IEBGENER (or similar program) to add a member and did not specify the member name.

blocks . : 0 * 1st extent blocks . : 78 Number of members . : 0 * Secondary blocks . : 100 Data set name type : PDS Creation date If allocating via TSO ALLOC command, coding should be: ALLOC DD(mydd) DA(mydsn) SPACE(xx yy) DIR(dd) etc... The same results will be true in most cases for a PDS. Thanks for the patience.

Looking at the above dataset attribute, I can see a "*" symbol beside Maximum dir. With today's technology you do not need to worry so much about disk rotation speed. Cheers Kolusu_________________Kolusu - DFSORT Development Team (IBM) DFSORT is on the Web at: www.ibm.com/storage/dfsort Back to top Display posts from previous: All Posts1 Day7 Days2 Weeks1 Month3 Months6 Months1 YearOldest FirstNewest zLog Board index Glossary FAQ Search Unanswered topics Active topics Disclaimer The team Downloads Rules Login Register Unanswered topics Active topics Disclaimer Glossary FAQ Search The team Downloads Rules Mainframe, MVS

Can handle OBJECTS as well as old style PDS data. https://groups.google.com/d/topic/bit.listserv.ibm-main/x-wvLLJSyP0 zPDT provides a System z system on a PC capable of running current System z operating systems, including emulation of selected System z I/O devices and control units. By using our services, you agree to our use of cookies.Learn moreGot itMy AccountSearchMapsYouTubePlayNewsGmailDriveCalendarGoogle+TranslatePhotosMoreShoppingWalletFinanceDocsBooksBloggerContactsHangoutsEven more from GoogleSign inHidden fieldsBooksbooks.google.com - This IBM® Redpaper Redbooks® publication provides both introductory information and technical Thereby writing over the directory blocks at the beginning of the dataset.

In case you’ve any concern, please write to [email protected] In most cases full track blocking will work fine. The amount of data you can write is dependent on the lrecl and blksize. Posting in capitals is rude as it means shouting.

The primary reason for this merger is to provide simpler zPDT documentation usage when viewing or searching the documentation onscreen. I tried browsing several members but I get the same error message. Regards, Jags Jags, Some thoughts. However, some benefits - PDS/E does not need to be compressed.

When zPDT is installed (on Linux), normal System z Operating Systems (such as IBM z/OS®) may be run on it. If you wish to experiment, take your syslog data. When zPDT is installed...https://books.google.com/books/about/IBM_zPDT_Guide_and_Reference_System_z_Pe.html?id=oGVyCAAAQBAJ&utm_source=gb-gplus-shareIBM zPDT Guide and Reference: System z Personal Development ToolMy libraryHelpAdvanced Book SearchGet print bookNo eBook availableAmazon.comBarnes&Noble.comBooks-A-MillionIndieBoundFind in a libraryAll sellers»Get Textbooks on Google PlayRent and save from

zLog Portal Board index Information Board is disabled for maintenance and will be unavailable for some time.

The IBM order numbers for the three volumes are SG24-7721, SG24-7722, and SG24-7723.The systems discussed in these volumes are complex, with elements of Linux (for the underlying PC machine), z/Architecture® (for Read, highlight, and take notes, across web, tablet, and phone.Go to Google Play Now »IBM System z Personal Development Tool: Volume 3 Additional Topics, Volume 3Bill Ogden, IBM RedbooksIBM Redbooks, Jun An IEBGENER Example which Trashes the Directory : //S0001 EXEC PGM=IEBGENER //SYSPRINT DD SYSOUT=* //SYSUT1 DD DISP=SHR,DSN=some.sequential.data //SYSUT2 DD DISP=SHR,DSN=mypds //SYSIN DD DUMMY Note on SYSUT2 there is no member specified. References: BLDL error Cause From: jagadishan perumal Prev by Date: Re: LINKLIST and ALIAS Next by Date: Re: LINKLIST and ALIAS Previous by thread: Re: BLDL error Cause Next by thread:

This topic has been discussed earlier. Back to top kolusuSite AdminJoined: 26 Nov 2002Posts: 11548Topics: 74Location: San Jose Posted: Wed Aug 11, 2004 9:49 am Post subject: Sejjobs, Please search before posting . Look at the attributes. PDS data sets need to be compressed and cannot be used to hold OBJECTS.

zPDT provides a System z system on a PC capable of running current System z operating systems, including emulation of selected System...https://books.google.com/books/about/IBM_System_z_Personal_Development_Tool_V.html?id=HFbAAgAAQBAJ&utm_source=gb-gplus-shareIBM System z Personal Development Tool: Volume 3 Additional TopicsMy This will over write the PDS Directory in many cases and there by destroying the PDS. Preview this book » What people are saying-Write a reviewWe haven't found any reviews in the usual places.Selected pagesPage 231Page 314Page 26Page 7Page 91ContentsChapter 1 Introduction1 Chapter 2 Function releases content5 After that, the original members will be accessible again.

Powered by phpBB Forum Software © phpBB Limited Time: 0.382s | Queries: 33 | Peak Memory Usage: 19.35 MiB Login • Register Username: Password: I forgot my password Remember zLog Portal Board index Contact us Delete all board cookies About Us Privacy Policy All times are UTC+05:30 1,368,121 Page visits Copyright © 2013 - 2016. The third volume discusses more advanced topics that may not interest all zPDT users. We assume the reader is familiar with the general concepts and terminology of System z hardware and software elements and with basic PC Linux characteristics.

blocks . : 0, but i am unable to interpret the exact cause. The systems that are discussed in this document are complex, with elements of Linux (for the underlying PC machine), IBM z/Architecture® (for the core zPDT elements), System z I/O functions (for The second volume describes the installation of zPDT (including the underlying Linux, and a particular z/OS® distribution) and basic usage patterns. Preview this book » What people are saying-Write a reviewWe haven't found any reviews in the usual places.Selected pagesPage 97Page 159Page 163Page 80Page 77ContentsChapter 1 General usage1 Chapter 2 Tapes SCSI

When in turn lead to the use of 1/4 and 1/2 blocking on disks. Could anyone please suggest me your comment on query. Is there a way of fixing it? Lizette ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html .

Mitt kontoSökMapsYouTubePlayNyheterGmailDriveKalenderGoogle+ÖversättFotonMerWalletDokumentBloggerKontakterHangoutsÄnnu mer från GoogleLogga inDolda fältSök efter grupper eller meddelanden Re: CORRUPT PDS - I/O ERROR From: [email protected] (CM Poncelet) Date: 26 Jul 2011 15:45:23 -0700 This can happen with zPDT provides the basic System z architecture and provides emulated IBM 3390 disk drives, 3270 interfaces, OSA interfaces, and so forth.This current document merges four separate previous Redbooks publications into this All rights reserved. Read, highlight, and take notes, across web, tablet, and phone.Go to Google Play Now »IBM zPDT Guide and Reference: System z Personal Development ToolBill Ogden, IBM RedbooksIBM Redbooks, Apr 20, 2015