Home > Hp Designjet > Hp Designjet 350c Error

Hp Designjet 350c Error

Push the front panel from the outside, to check whether it is correctly installed. Reassembling: Close the cover and click each hinge into place. 4 Remove the cover from the plotter. Melde dich an, um dieses Video zur Playlist "Später ansehen" hinzuzufügen. The system returned: (22) Invalid argument The remote host or network may be down. Check This Out

X Safety C4699-90000 Product Information 1-1 Description Applications HP DesignJet 230 and 330 (monochrome) and HP DesignJet 250C and 350C (color) plotters are large-format, ink-jet plotters that print output from software NOTE: If the same cartridge works in another slot, clean the cartridge slot with a clean cloth to make sure that a proper electrical connection is made. It appears to have power, but 10/16/2016 10/16/2016 Anthony Trying to set date and time m1033 camera. Your cache administrator is webmaster. see this here

These may be stiff. 4 Pull the end-cover up, and remove it from the plotter. When roll media is loaded into the plotter, it is passed around a diverter roll, which optimizes the infeed path to the plotter. Disconnect all cables from the visible part of the main PCA. Device-Control Languages The plotters support the following languages, enabling the user to read certain plotter settings from the computer: • Printer Job Language (PJL) • Printer Management Language (PML) 1-2 Product

C4699-90000 Preventive Maintenance 4-3 Cleaning the Plotter To maintain the plotter in good operating condition, keep it free of dust accumulation, ink, and other contamination. Black plastic piece Disconnecting the Front-Panel Assembly 1 Remove the right end-cover ^ page 6-10. 2 On the main PCA, gently pull the front-panel connector clamp (FP) to the right to Dirty contacts, the wrong type of cartridge, a defective carriage slot, or a bad top cover sensor are some of the causes for a bad electrical connection. The accuracy calibration is now complete.

Wait until the ink on the sheet is dry. Retain the shipping container and insulation material for the carrier's inspection. Loading Sheet Media The actions performed by the plotters in loading sheet media are similar to those of the DesignJet 220. (There are some differences due to the different position of Do not use abrasive cleaners. 3 Wipe the plotter dry with a soft lint-free cloth.

I tried to do a 10/17/2016 10/17/2016 Richard I have a Pioneer SX750 that I have not powered up in 10 10/17/2016 10/17/2016 Aric No response on the keys after resetting A terminal marked with this symbol must be connected to ground in the manner described in the installation (operating) manual, and before operating the equipment. Use a sheet of approximately D-size (24 x 36 inches / 61 x 91 cm). If a failure or damage to such HP products is found to be directly attributed to the use of third-party inks or off-axis ink systems (or any other non-supported HP supply

Never place the bushings on an absorbant material. Wird verarbeitet... Return to TWI Documents Library Index Page HP Designjet 350C Series Printers - Pen Rejection, Flashing Film + Error LEDs In this document: Parts required (part numbers are subject to change) After realigning, the right edge of the media is checked again for skew (misalignment). (The loading process fails if the skew is greater than the allowed limits or if the aligned

Belt Swelling To prevent new belts from swelling incorrectly, keep them in their bags with dissicant until you need to install them. his comment is here If you have any cartridges nearly dry and they have been inb for a while, i would suspect that cartridge. C4699-90000 Installation and Configuration 3-5 r^ f^ 3-6 Installation and Configuration C4699-90000 A -32Kg (-71 lb) n E/AO-size plotters only. The servo processor uses the sensor to determine the pinch-arm position during the initialization sequence.

The CAUTION sign denotes a hazard. Please help Submitted: 7 years ago. by floppy_77 on Mar 28, 2008 at 7:10pm Add comment Please sign in to comment 0 Saw one not to long ago and it was not a firmware issue, but rather this contact form Electrostatic Discharge Refer to the beginning of Chapter 6 of this manual, for precautions you should take to prevent damage to the plotter circuits from electrostatic discharge.

I/O Timeout o CD Italiano O 9600 CD 0.5 min Mirror on CD Portugues CD 19200 CD 38400 CD 5 min o Merge off <7> 30 min CD Merge on 6. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of Hewlett- Packard Company. A longer cable is permissible, provided the load capacitance does not exceed 2500 picofarads.

Cycle power, service Error+ Ready+ Roll Special firmware error Cycle power, service Plain+ Error+ Fast Error detected in EEROM Cycle power, service Plain+ Error+ Roll Processor fault Cycle power, service Plain+Load

A similar error could occur on all 400 Series including the 430/450/455/488 Series. Page Size /sest O /best O Best O El O Inked Area O Software O /Best O 1^0 1 AO / B1 O 1 D O 1 A1 1 ^ ANsI A -32Kg (-71 lb) 3-2 Installation and Configuration C4699-90000 A C4699-90000 Installation and Configuration 3-3 Inspecting the Plotter for Damage Visually inspect the plotter for damage, scratches, dents, or other mechanical Mark parity is not supported.

If functionality is verified, no additional parts should be replaced. by dmzcompute on Mar 28, 2008 at 7:22pm Add comment Please sign in to comment 0 Hi, I managed to fix mine a while ago.It turned out to be the circuit Power-On Self-Tests Whenever you switch the plotter on, it automatically performs a series of internal self-tests and mechanical initialization sequences. navigate here The power-on LED sequence tells you whether the plotter is using code from in-built ROM or from a ROM SIMM. (Details i^ page 8-3.) To find out the firmware-code revision level

The HP DesignJet 230 and 250C originally replaced the DesignJet 220 but are now no longer produced. Installing the incorrect primer can damage the cartridges or reduce the servicing of the cartridges. Hewlett-Packard shall not be liable for any direct, indirect, special, incidental or consequential damages in connection with the use of this material. Web computercare.cc If the issue persists, replace the Electronics module (refer to pages 6-13 of the 300 Series Service Manual).

C4699-90000 Functional Overview 5-5 Providing a Force on Top of the Media Bail The bail provides a normal force on top of the media. Attempt to verify functionality. With power off manually move carriage Plain+ Load Media+Error+film Problems with the free movement With power off manually move of the carriage Plain+ Error+ Film+Normal Electrical error Reseat all cartridges, Clean Some types of graphics require relatively large amounts of memory.

Wird geladen... Über YouTube Presse Urheberrecht YouTuber Werbung Entwickler +YouTube Nutzungsbedingungen Datenschutz Richtlinien und Sicherheit Feedback senden Probier mal was Neues aus! The CPU needs to be satisfied and it is the cartridges that satisfy it before it will boot. Cleaning the Roll-feed Assembly Always clean the rubber diverter of the roll-feed assembly with a dry cloth. Data flows through the plotter without being stored in a display list, so the size of the file that you can send is almost unlimited.

The vertical arrows represent movement of the media. Graphics Language o CD HP-GL (7586B) HP-GL/2 4 I/O Timeout CO CO o o 0.5 min 1 min 5 min 30 min 5. Spring hook. Anmelden 26 0 Dieses Video gefällt dir nicht?

The system returned: (22) Invalid argument The remote host or network may be down. The pinch-arm sensor detects whether the pinch-arms have been raised. The Ready LED should be on, indicating the top cover is closed. Unlike the DesignJet 650G, they have no modular input/output (MIO).