In general as rule of thumb an SVC improves the given IOPS from the underlying array by 10-15%. -Roger Reply John Mathew / October 6, 2013 Thanks Roger … Regards John Harsh Top For discussions on IBM Storage please visit the Storage - General Discussions group. This state can also occur when a relationship is created with the CreateConsistentFlag set to TRUE.Did you receive any Error in the Log, like 1700 or else ? -Roger Reply Johnny And the FCIP Link lays in this connection.(The line is for personal use usually, they use it because of Budget,but not a leased line : http://www.cht.com.tw/personal/hinet.html) Their environment is VMs store http://upintheaether.com/error-code/ibm-db2-error-code.php

I am pretty sure that bandwidth was not the cause as it happens only on a particular day in a week (basically weekly basis). More Storage Groups Your account is ready. Does Global Mirror cost the cache only when the bandwidth is not enough, and data is congested in the source side? Regards John Reply rogerluethy / October 6, 2013 Hi John A 1630 points to lost link to the backend Storage i.e. https://www.ibm.com/support/knowledgecenter/STPVGU/com.ibm.storage.svc.console.720.doc/code_1630.html

Svc Error Codes

Disks 'Define' But Not Available In AIX SVC MPIO for backing storage Load balancing in IBM DS4800 with AIX 5.3 serial numbers lscfg details 7BFEEA1F Error On VIO - AIX IBM It appears you deep linked too, so we can take it down, but I'd rather just a tip of the hat with a link to our site🙂 https://rogerluethy.wordpress.com/2012/09/11/designing-hybrid-storage-for-the-enterprise/ Reply rogerluethy / Fill in your details below or click an icon to log in: Email (required) (Address never made public) Name (required) Website You are commenting using your WordPress.com account. (LogOut/Change) You are

The errors will not clear on their own. Reply rogerluethy / October 1, 2013 Hi Johnny, This can happen in the following cases. There is no default user name and password. V3700 Error Code 2030 SAN router`s FCoIP channel QoS = 1Gbps (as 125 MB/s) Both side`s V7000 partnership `s bandwidth = 100MB/s Both side`s V7000 relationship`s bandwidth = 90MB/s Any suggestion ?

Michelle Top Best Answer 0 Mark this reply as the best answer?(Choose carefully, this can't be changed) Yes | No Saving... Svc Error Code 2030 Reply John Mathew / October 16, 2013 Hi Roger , In an IBM SVC there is a global mirror configuration set. .Is it possible to check the bandwidth consumed by each If you start the IBM DS Storage Manager for the first time you need to set a user and a password. The best information will be showed by the lsrcrelationship command.

You can find more details in the SVC Information Center ->http://pic.dhe.ibm.com/infocenter/svc/ic/index.jsp or in the Redbook ->http://publib-b.boulder.ibm.com/abstracts/sg247574.html Chapter 3 also 3.10 Hope this helps -Roger Reply John / April 26, 2013 Thanks V7000 Troubleshooting, Recovery And Maintenance Guide Join this group 3Replies Best Answer 0 Mark this reply as the best answer?(Choose carefully, this can't be changed) Yes | No Saving... You may try in the CLI svcinfo lssystemstats -nohdr -history cpu_pc to get some Perf History Please see also ->http://aussiestorageblog.wordpress.com/2012/06/22/storwize-v7000-and-svc-performance-monitoring/ -Roger Reply Johnny / October 1, 2013 Hi We help customer Sorry for my english, i am from Russia.

Svc Error Code 2030

Nice ! Use QoS there to guarantee the Bandwidth needed for the Global Mirror connections. Svc Error Codes There's a ironic twist if this is the case because one of the benefits that V07.84 is designed to give is additional "base" partitions. Node Warmstarted Due To An Internal Error Reply rogerluethy / March 26, 2014 Hi Alex You can't replace a Disk on your own on a IBM XIV (2810-A14) System.

Solve problems - It's Free Create your account in seconds E-mail address is taken If this is your account,sign in here Email address Username Between 5 and 30 characters. useful reference MoreWhitePapers Best Answer 0 Mark this reply as the best answer?(Choose carefully, this can't be changed) Yes | No Saving... Do you receive ‘1920' errors ? -Roger Reply JimmyChien / October 17, 2013 Hi Roger 1920 is the error code I did adjust this parameter already The default setting for gmlinktolerance Happy to help. -Roger Elena / July 16, 2013 Hi Roger, I'd like to know is there an opportunity to publish a guest article/post on your blog? Managed Disk Error Count Warning Threshold Met V7000

The IBM Storage group is no longer active. 3210364 Related Discussions Number of Device Paths Has Reduced/Device Logins Reduced DS4800 SDD and SVC vpaths Fibre Link Issue SVC multipathing IBM SVC SVC has lost one or more links. The request cannot be fulfilled by the server The request cannot be fulfilled by the server United States English English IBM® Site map IBM IBM Support Check here to start http://upintheaether.com/error-code/ibm-jcl-error-code.php Why then did this error crop up?

In the Management Console go to "Monitoring" and then "Performance" there you can see the CPU load. -Roger Reply John / September 17, 2013 Thanks Roger , I saw that in Error Sans This issue can only be encountered during a node restart. They're generally a lot saner than this IBM stuff.

I will bring this information to our Development. -Roger Reply Brian Beeler / March 5, 2013 Roger - it's come to our attention today via Seagate's blog that you used our

Reply JimmyChien / October 17, 2013 Hi Roger I will try to change gmmaxhostdelay. Cross reference information Segment Product Component Platform Version Edition Disk Storage Systems IBM Storwize V7000 (2076) 6.3 IBM Storwize V7000 6.3 Disk Storage Systems IBM Storwize V7000 Unified (2073) 1.3 IBM You may need to adjust the values there if the connection is unstable and can't provide always the needed Bandwidth. This can happen if something is wrong with the SAN Zoning or you have a bad port in the SAN. -Roger Reply John Mathew / October 6, 2013 Thanks Roger ..

Each time we start the Global Mirroring and wait the status become to "Consistent Synchronized " , after 1 day or few days, the status become "Consistent Stopped" by itself. I will remove it immediately. -Roger Reply Shortie / April 15, 2013 Hi, I was wondering if anyone else has encountered an issue with the loss of available partitions on an Reply John / April 26, 2013 Thanks Roger . http://upintheaether.com/error-code/ibm-error-code-192.php the delay may be disappear, right?

Unfortunately, the guy who managed the SVC is no longer working for us and I am (to be honest) not familiar with the configuration of the SVC. I am contacting you and any reader here, regarding MPIO driver for IBM DS3500 series, and memory leak it causes. Ignore this text box. In metro and global mirror relationship tab there is a row which shows the percentage of data transfer for each volume .

They also suggested we fix the problem before we update the firmware... I will post it asap. -Roger Reply Joe / January 15, 2014 Hope you have a great vacation! We have a global mirror configured between two sites, We are planning to shutdown the host connected to primary and breaks the global mirror after some time .Is it possible to Please see here ->http://pic.dhe.ibm.com/infocenter/svc/ic/topic/com.ibm.storage.svc.console.620.doc/svc_lsrcrelationship_21pdzi.html?resultof=%22%73%79%6e%63%22%20 -Roger Reply John / April 26, 2013 Thanks Roger , John rogerluethy / April 26, 2013 You're welcome ! -Roger John / April 26, 2013 Sorry to

We thought your readers might find it useful. I had a small query regarding svctask chcluster -gminterdelaysimulation , will this setting delay the vdisk replication . Cesar Delgado replied Jan 3, 2010 Hi It could be some chancges in the SAN zoning that excluded the SVC ports of the original zones so when SVC looks for its Lab Validation Report: IBM Tivoli Storage manager for ...

No spaces please The Profile Name is already in use Password Notify me of new activity in this group: Real Time Daily Never Keep me informed of the latest: White Papers and a 4TB LUN, (600MB used for Flash Copy for VMWare SRM ), someone suggest me to separate into two LUNs, then I can make good use of two controller. Regards John Reply rogerluethy / November 21, 2013 Hi John, Yes thank you hope you are fine too. Basically when trying to check with tperf it reports very huge RTT values in medium priority, where as ping reports 30-40ms , but with these many packet loss.

All rights reserved. Did you try the Redbook ->http://www.redbooks.ibm.com/redbooks/pdfs/sg247065.pdf ? I am learning as I go. Mickey Baker replied Nov 11, 2015 It appears that you have lost one of the following: Fibre channel port on the SVC; Fibre channel port on your storage controller; Fibre channel

It works better for DS3500 than SVC It's a pain, that we must use HP tool to get something. There seems to be a problem with the WAN link quality.