Home > Error Code > Ibm 162 Error Code

Ibm 162 Error Code

Contents

Replace the following components one at a time, in the order shown, restarting the blade server each time: (Trained service technician only) Microprocessor - See Removing a microprocessor and heat sink Hot-swap storage drive - See Removing a hot-swap storage drive and Installing a hot-swap storage drive. Run the Configuration/Setup Utility program (Using the Configuration/Setup Utility program), select Load Default Settings and save the settings. Replace the following components one at a time, in the order shown, restarting the blade server each time: Battery - See Removing the battery and Installing the battery. (Trained service technician click site

Run the Setup utility and select System Information > System Summary > Processor Details to view the microprocessor information to compare the installed microprocessor specifications. (Trained service technician only) Remove and Reflash BIOS code. Reseat the storage drive. Reseat the DIMMs and restart the server.

Ibm Error Codes

Error code Description Action 062 Three consecutive startup failures Run the Configuration/Setup Utility program (Using the Configuration/Setup Utility program), select Load Default Settings, make sure that the date and time are Reflash BIOS code. Microprocessor 1 01298002 (No update data for processor 2) Ensure all microprocessors are the same cache size. I/O board 151 (Real time clock error) Battery I/O board 161 (Real time clock battery error) Battery I/O board 162 (Device Configuration Error) Note: Be sure to load the default settings

Remove each I/O expansion card one at a time, restarting the blade server each time, until the problem is isolated. See Using the Configuration/Setup Utility program. It is provided on an "AS IS" basis, with no warranties of any kind. Parity Error Message Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit. 301 Keyboard failure.

Run the Setup utility, select Load Default Settings, and save the settings. If the problem remains, replace the failing DIMM. (Trained service technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. Run the Setup utility and select System Information > System Summary > Processor Details to view the microprocessor information to compare the installed microprocessor specifications. (Trained service technician only) Remove and check my blog Applicable countries and regions In the following error codes, X can be any number or letter.

When an adapter fails, replace it. 00180600 (A PCI-to-PCI bridge error occured. What Dos Command Do You Use To Erase A Hard Drive And Make It Bootable? Disabling the adapter BIOS on the adapter should correct the error. Remove each optional device one at a time, restarting the blade server each time, until the 1801 error code is cleared. Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.

162 Configuration Error Ibm Server X3650

Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server. https://www.ibm.com/support/entry/portal/docdisplay?lndocid=migr-55364 If you can start the server without the adapters, reinstall each adapter one at a time and restart after each one is reinstalled. Ibm Error Codes If the connector contains any foreign material or is damaged, replace the system board. (Trained service technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged How Many Digits Are In A Mac Address? Reseat the I/O expansion card in slot xx; then, restart the blade server.

If the connector contains any foreign material or is damaged, replace the system board. (Trained service technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged http://upintheaether.com/error-code/hp-error-code-303-305.php If the memory resource settings are not correct, change the settings. If an optional expansion unit is installed, reseat it - See Removing an optional expansion unit and Installing an optional expansion unit. Installing the operating system. Ibm Checkpoint Codes

See Using the Configuration/Setup Utility program. See Parts listing, IBM System x3550 M3 Type 4254 and 7944 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). Use the Configuration/Setup Utility program (Advanced Setup → PCI Bus Control → PCI ROM Control) to disable each optional device one at a time, restarting the blade server each time, until navigate to this website The second part gives the meaning of the error.

Update the server firmware to the latest level (see Updating the firmware). (Trained service technician only) Reseat microprocessor 2. Ibm Post Error Codes Microprocessor 1 01298002 (No update data for mircoprocessor 2) Ensure all processors are the same stepping level and cache size. If the memory resource settings are not correct, change the settings.

More than one PCI bus tried to access memory below 1 MB.) Remove the PCI adapter that has the PCI bridge.

This page is rather extensive and will be updated on a regular basis. If an optional expansion unit is installed, reseat it - See Removing an optional expansion unit and Installing an optional expansion unit. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility Ibm Post Beep Codes I9990303 No Boot devices found Install the operating system on the storage drive - See Installing the operating system.

Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit. (Trained service technician only) System-board assembly - See Removing the system-board Switch the bank back to the primary bank. (Trained service technician only) Replace the system board. 3818007 CRTM update capsule signature invalid Run the Setup utility, select Load Default Settings, and Battery I/O board 186 (Security hardware control logic failed) Run Configuration/Setup. my review here Replace the following components one at a time, in the order shown, restarting the blade server each time: Storage drive - Depending on your storage-drive configuration, replace one of the following:Fixed-storage

Check service processor in host. If the problem is related to a DIMM, replace the failing DIMM. (Trained service technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. Failing adapter I/O board 00180400 (No more memory (below 1MB for PCI adapter)) Run Configuration/Setup. Run the Setup utility and select System Information > System Summary > Processor Details to view the microprocessor information to compare the installed microprocessor specifications. (Trained service technician only) Remove and

See Turning off the blade serverRemoving an I/O expansion card and Turning on the blade server. Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server. See Turning off the blade serverRemoving an I/O expansion card and Turning on the blade server. Refer to documentation provided with the adapter. 00180200 (No more I/O space available for PCI adapter) Run Configuration/Setup.

Run Configuration/Setup. Replace the following components one at a time, in the order shown, restarting the blade server each time. It is important that your boot device is positioned early in the scan order so that it is executed by POST. Make sure that the operating system is not corrupted.

Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error. Memory online-spare channel has been activated to back up a failed DIMM. Replace the following components one at a time, in the order shown, restarting the blade server each time: Failed I/O expansion card - See Removing an I/O expansion card and Installing Footer links Contact Privacy Terms of use Accessibility Select a country/region: United States IBM® Site map Search Select a language Translate this page Return to English Portuguese French German Italian

Check RIOG cable. 01295085 (ECC checking hardware test error) Microprocessor DIMM Microprocessor tray assembly 01298001 (No update data for processor 1) Ensure all microprocessors are the same cache size. See the following optional device procedures: I/O expansion card - See Removing an I/O expansion card andInstalling an I/O expansion card. Reseat all affected adapters and riser cards. Failing adapter I/O board 00180700, 00180800 (General PCI error) Verify that no devices have been disabled in CMOS.

See error code 00151500 to determine which DIMM to replace. 00151710 Completed Hot Spare memory Copy. See Using the Configuration/Setup Utility program. If an optional expansion unit is installed, reseat it - See Removing an optional expansion unit and Installing an optional expansion unit. Run the Setup utility and select System Information > System Summary > Processor Details to view the microprocessor information to compare the installed microprocessor specifications. (Trained service technician only) Remove and